Honeywell and AxxonSoft Technology Partnership
AxxonSoft integrates selected Honeywell security systems and Honeywell alarm systems into Axxon PSIM using dedicated integration modules. Supported solutions include Esser by Honeywell fire alarm panels and Honeywell VISTA intrusion alarm systems, enabling centralized monitoring, control, and event management within a single PSIM platform.
By consolidating fire alarms, intrusion events, partitions and zones into one interface, Axxon PSIM enables unified supervision of Honeywell security alarm systems, simplifies alarm handling, and supports scalable deployments across professional and enterprise environments.
Quick Overview and Key Benefits of the Honeywell + AxxonSoft Integration
Integration at a Glance
The Honeywell integration module connects Honeywell alarm panels and fire safety systems to Axxon PSIM, enabling centralized supervision of alarms, zones, partitions, and system states. Events from Esser by Honeywell fire alarm systems and Honeywell VISTA intruder alarm systems are received in real time and visualized within Axxon PSIM together with other connected security and safety subsystems.
The integration is software-based and designed for professional Honeywell security systems deployments where reliability, regulatory compliance, and centralized control are essential.
Key Advantages
- Unified alarm management — fire alarms, intrusion alarms, partitions, and zone states from Honeywell alarm systems are monitored from a single PSIM interface.
- Improved alarm response — centralized visualization enables faster alarm verification and consistent operator workflows.
- Scalable architecture — supports multi-panel, multi-zone, and multi-site security system Honeywell deployments.
- Professional fire alarm integration — direct integration with Esser by Honeywell fire alarm panels, widely used in regulated environments.
- Reduced operational complexity — operators manage multiple Honeywell security alarm systems without switching between standalone tools.
How It Works — Honeywell Fire & Intrusion Integration Architecture
Axxon PSIM connects to Honeywell alarm equipment through supported AxxonSoft integration modules and approved communication interfaces.
For Esser by Honeywell fire alarm systems, the integration uses the SEI2 communication module, which enables connection via RS232 to the Essernet network. Fire alarm control panels such as FlexES Control and IQ8Control transmit alarms and system status information into Axxon PSIM.
For Honeywell VISTA intrusion systems, Axxon PSIM receives zone-level and partition-level events from the intrusion alarm panel through a Honeywell server, enabling centralized monitoring of Honeywell intruder alarm activity.
Once connected, Axxon PSIM consolidates incoming events from Honeywell security systems into a unified event stream used for alarm display and acknowledgment within Axxon PSIM.
Honeywell Esser Fire Alarm Integration
The AxxonSoft Honeywell Esser integration module provides connectivity to Esser by Honeywell fire alarm control panels, including FlexES Control and IQ8Control.
These Honeywell alarm system panels operate as the primary fire detection and control layer, managing fire alarm logic and system states. Axxon PSIM does not replace the fire alarm control system; instead, it acts as a supervisory layer that receives and visualizes fire-related events and technical states in real time.
Panel-level data exposed to Axxon PSIM includes:
- Fire alarms and related system events.
- Faults and technical warnings.
- Panel status and communication states.
- System status indicators.
This architecture allows Axxon PSIM to supervise Honeywell fire alarm systems while preserving the autonomy of the fire alarm control panel.
Fire Alarm Monitoring & Control
Axxon PSIM receives fire alarm events from Honeywell alarm panels, allowing operators to:
- Monitor alarms and faults centrally.
- Receive event verification clips from associated cameras.
- Locate alarm zones on the map.
- Track panel and system states.
- Acknowledge and process alarms in real time.
- Coordinate alarm handling across sites.
All life-safety control logic remains on the Honeywell fire alarm panel, ensuring regulatory compliance.
Communication via SEI2 Module (RS232 → Essernet)
Integration is implemented using the SEI2 module, which bridges RS232 communication to the Essernet network:
- The Honeywell Esser fire alarm panel outputs events via RS232.
- The SEI2 module transfers data into the Essernet network.
- Axxon PSIM connects to the Essernet interface.
- Incoming messages are mapped to PSIM alarm objects.
This approach ensures reliable data exchange between Honeywell alarm equipment and Axxon PSIM.
Honeywell VISTA Intrusion System Integration
Axxon PSIM integrates with Honeywell VISTA SUPER II intrusion alarm systems at the zone and partition level, reflecting the internal structure of the Honeywell burglar alarm system.
Within Axxon PSIM:
- Each intrusion zone becomes a discrete alarm object.
- Partitions represent logical security areas.
- Zone states (normal, alarm, fault, bypassed) are tracked in real time.
This ensures accurate supervision of Honeywell security alarm panels.
Intrusion Event Processing and Alarm Handling
When an intrusion event occurs, the Honeywell VISTA alarm panel transmits the event to Axxon PSIM, which then:
- Identifies the affected zone and partition.
- Classifies and prioritizes the event.
- Displays alarms in operator consoles (map, event log, linked video).
- Applies predefined alarm handling logic.
Unified Fire and Intrusion Supervision
By integrating Honeywell fire alarm systems and Honeywell VISTA intrusion alarms, Axxon PSIM establishes a unified supervisory layer for multiple safety domains.
From a system perspective:
- Fire and intrusion alarms are normalized into a common PSIM event model.
- Operators use consistent acknowledgment and handling logic.
- Joint visualization of Honeywell security alarms is provided within a single interface.
Use Cases
Commercial & Office Buildings
Centralized supervision of Honeywell alarm systems across multiple buildings.
Healthcare & Education Campuses
Centralized alarm handling for complex, multi-building environments.
How-To Installation Guide
- Install and configure the Honeywell fire or intrusion alarm panel according to manufacturer guidelines.
- Connect the panel using the supported communication interface.
- Configure the Honeywell integration module in Axxon PSIM.
- Define controllers, partitions, and zones.
- Verify communication and test alarms.
- Assign operator workflows.
Installation Guide & Documentation
Full technical documentation, compatibility tables and detailed installation steps are available in the AxxonSoft Confluence docs. If you are an integrator or systems engineer, please request access through our tech support.
Book a personalized demo to explore how AxxonSoft intelligent video management software integrates with a wide range of security, analytics, and automation technologies. Discover the capabilities, workflows, and performance benefits that can help you enhance operational efficiency, strengthen security, and bring value to your organization faster.
FAQ — Honeywell & AxxonSoft Integration
What Honeywell security systems are supported by Axxon PSIM?
Axxon PSIM supports selected Honeywell security systems, including Esser by Honeywell fire alarm panels and Honeywell VISTA intrusion alarm systems, subject to hardware compatibility and licensing.
Can Axxon PSIM integrate with a Honeywell alarm system panel?
Yes. Axxon PSIM integrates with supported Honeywell alarm system panels, enabling centralized monitoring of fire and intrusion alarms.
Does Axxon PSIM support Honeywell VISTA intrusion alarms?
Yes. Honeywell VISTA SUPER II intrusion alarm panels are supported at the zone and partition level.
How does Axxon PSIM connect to Honeywell fire alarm systems?
Honeywell fire alarm systems are connected using the SEI2 module, which provides RS232-to-Essernet communication between the fire alarm panel and Axxon PSIM.
Can multiple Honeywell alarm systems be monitored in one interface?
Yes. Axxon PSIM supports centralized supervision of multiple Honeywell alarm systems across panels and sites.
Is this integration suitable for enterprise Honeywell security systems?
Yes. The integration is designed for professional and enterprise-grade Honeywell security systems used in regulated and multi-site environments.
Are zone-level events supported for Honeywell intrusion alarms?
Yes. Honeywell intrusion alarm events are processed at the zone and partition level within Axxon PSIM.
Does Axxon PSIM replace the Honeywell alarm control panel?
No. Axxon PSIM acts as a supervisory platform and does not replace the Honeywell alarm panel or its control logic.
Can fire and intrusion alarms be viewed together?
Yes. Axxon PSIM provides joint visualization of Honeywell fire alarm systems and Honeywell security alarm systems in a single interface. It also provides map visualization and alarm verification video from associated cameras.
Is licensing required for Honeywell alarm system integration?
Yes. Integration with Honeywell alarm systems requires appropriate AxxonSoft licensing, as described in the official documentation.